Installation
GB
First, remove the wallplate from the back of the unit.
From the top left hand corner of the wallplate, there must be
clearances of at least 150mm to the right, 15mm to the left, 0mm
above and 100mm below in order to mount the plug-in module.
Fix at a height of approximately 1.5m from the floor, away from
draughts or heat sources such as radiators, open fires or direct
sunlight.

Thermostat Wiring

1
OFF
!
Some existing thermostats will have a Neutral and/or Earth wire connected.
These are not required by the TP4000 and must NOT be connected to any TP4000
terminals. Instead they should be made electrically safe and coiled in the recess at
the back of the TP4000.

N/C
N/O
2 3
COM
ON