Wiring - Danfoss TP9000 Guia De Instalacion

Termostato de ambiente electrónico programable con temporizador doméstico de agua caliente
Ocultar thumbs Ver también para TP9000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1.2 Wiring

NOTE:
The 230V TP9000 does not have voltage free contacts, therefore it is
NOT suitable for connection to extra low voltage equipment.
Remote Sensor to be wired with 1mm 2 core double insulated cable
only. Cable length should not exceed 50 metres. Sensor cable should
NOT be run parallel to mains cable.
N
B
Remote sensor inputs
The TP9000 incorporates an input which can be used to connect one
of the following:
1) remote room temperature sensor
2) limit sensor, for example, fl oor temperature sensor (sold as
accessory).
3) window contacts, card reader contacts, outdoor sensor (sold as
accessory) or teleswitch contacts.
See Installer Advanced Programming Options for set-up
instructions.
Danfoss Heating
L
C
N-L = 230V
B-C = 24V
(B=0v / C=24v)
GB
GB
PL
GR
ES
7