BA230
MOTOR 1 DECELERATION
F2
SPEED 1
F5
MOTOR 2 FORCE
MOTOR 2 DECELERATION
F6
SPEED 2
MENU H: TIMES ADJUSTMENTS AND SETTINGS
All times can be set in steps of 1 s.
Menu
Function
H1
MOTOR 1 OPENING TIME
H2
MOTOR 1 CLOSING TIME
MOTOR 1
H3
DECELERATION TIME
H4
MOTOR 2 OPENING TIME
H5
MOTOR 2 CLOSING TIME
MOTOR 2
H6
DECELERATION TIME
LEAF 2 PHASE SHIFT TIME
H7
IN OPENING
LEAF 1 PHASE SHIFT TIME
H8
IN CLOSING
AUTOMATIC CLOSING
H9
PAUSE TIME
H10
PEDESTRIAN OPENING TIME
AUTOMATIC PEDESTRIAN
H11
CLOSING PAUSE TIME
H12
CYCLES NUMBER
H13
INSTALLER CODE
H14
SOFTWARE VERSION
H15
NUMBER OF PERFORMED CYCLES
(*) time must be sufficient to reach the limit switches
Adjusts motor 1 thrust during deceleration phase.
0001 = minimum force.
0010 =maximum force.
Adjusts motor 2 thrust.
0001 = minimum force.
0010 =maximum force.
Adjusts motor 2 thrust during deceleration phase.
0001 = minimum force.
0010 =maximum force.
Description
Leaf 1 opening time. (*) Tmax 300 s.
Leaf 1 closing time. (*) Tmax 300 s.
Leaf 1 operating time in deceleration mode. (*) Tmax 100 s.
Leaf 2 opening time. (*) Tmax 300 s.
Leaf 2 closing time. (*) Tmax 300 s.
Leaf 2 operating time in deceleration mode. (*) Tmax 100 s.
Delays the start in opening of leaf 2 with respect to leaf 1.
In the case of double sliding gate, the time H7 will not be considered.
Tmax 100 s.
Delays the start in closing of leaf 1 with respect to leaf 2. In the case of double sliding
gate, the time H8 will not be considered.
Tmax 100 s.
Determines the pause time in opening before the automatic closing.
Tmax 300 s.
Determines the pedestrian opening time. Tmax 300 s.
Determines the pause time in pedestrian opening before automatic closing.
Tmax 300 s.
Allows the setting of a number of cycles (opening + closing) before the maintenance
request.
The value set will always be multiplied for 10.
If 0000 is set, the numbering is excluded.
When the set number of cycles is reached, the maintenance request is signalled by a
slow blink of 60 sec. at the end of the movement.
WARNING: Every time you enter the menu H12, the cycles numbering is reset and
starts again.
Allows the input of the installer code to customize the settings in the programming
phase.
The INSTALLER CODE is the only way to enter the programming menu.
WARNING: in case of loss of the installer code, it will be possible to delete the old one
by pressing simultaneously the keys + and - for 3 s when the writing PASS appears.
In this way, all the existing settings are erased and the default ones are automatically
set. Only the settings of the performed cycles are still stored in memory.
Shows the firmware version installed on the equipment. (R__XX)
Number of performed cycles. The value displayed on the LCD is increased every 10
movements.