GiBiDi BA230 Manual De Instrucciones página 38

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
38
UK
MENU E: EXTERNAL DEVICES ENABLING-DISABLING
KEY + enters the following menu E1-E2-E3
KEY – enters the previous menu E3-E2-E1
KEY OK enables Y (yes). Enables the function.
KEY OK enables N (no). Disables the function.
KEY ESC leaves the menu.
WARNING: The STOP key cannot be excluded in menu E. If it is not used, jumper the clamps 22-32.
Menu
Function
E1
PHOTOCELL 1
E2
PHOTOCELL 2
E2
EDGE (SEFETY DEVICE)
TIMES MANAGEMENT
T3 ADDITIONAL TIME
Additional time at the end of the working time (with full force or during deceleration phase according to the
settings) that allows to continue the closing movement even if there is wind.
The T3 function is disabled with the sliding configuration.
During the T3 time, the anti-crushing is not active, so the T3 time must start as near as possible to the door
stroke.
The limit switch that determines T3 must not be exceeded to maintain the control of the limit switches in case of
motion inversion.
TIMES LEARNING PROCEDURE
CAUTION: start with the gate completely closed.
Times are programmed by means of sequences of START pulses.
Select the menu C21 to enter this procedure. (menu C21 blinking).
The times learning procedure starts by pressing OK (menu C21 Y fixed) then:
1 motor configuration
the leaf starts opening.
• START
• When the leaf arrives at the desired opening position
• Counting of the pause time in opening starts.
• When the desired pause time has elapsed
• When the leaf arrives at the closing position
• Now the procedure has finished, the menu C21 reappears blinking (without Y).
• If you want to repeat the operation, press OK.
• If you want to finish the times learning operation and save the data, press ESC as long as the horizontal lines appear on
the display.
2 motors configuration
leaf 1 starts opening
• START
leaf 2 starts opening
• START
Status
Description
Y
Photocell 1 enabled.
N
Photocell 1 disabled.
Y
Photocell 2 enabled.
N
Photocell 2 disabled.
Y
Edge enabled.
N
Edge disabled.
START
the leaf stops.
START
the leaf starts closing.
START
the leaf stops.
BA230