CIM 500 fitted in a CIU 500 (FOR GRM)
Fault (LED status)
1.
Both LEDs remain off when
the power supply is
connected.
2.
LED1 remains off.
3.
LED2 is flashing red.
4.
LED1 is flashing green.
5.
LED1 is permanently red.
6.
LED1 is flashing red.
7.
Can't access the CIU 500 on
the GRM interface.

7. Technical data

Internet protocol
Application layer
DHCP, HTTP, Ping
Transport layer
TCP
Internet layer
Internet protocol V4 (IPv4)
ARP, media access control
Link layer
(Ethernet)
Screened, twisted-pair
Ethernet cable
cables, CAT5, CAT5e or
CAT6
10 Mbit/s, 100 Mbit/s
Transmission speed
(auto-detected)
PROFINET IO, Modbus
Industrial Ethernet
TCP, BACnet IP, GRM IP
protocols
(requires a contract with
Grundfos)
Supply voltage
5 VDC ± 5 %, I
-25 °C to +70 °C
Storage temperature
-13 °F to +158 °F
Possible cause
a)
The CIU 500 is defective.
a)
SW1 is set to "1".
a)
No internal communication
between the CIU 500 and the
Grundfos product.
b)
No GRM driver loaded.
a)
120 seconds startup phase.
a)
The module does not support
the Grundfos product
connected.
b)
SW1 in illegal position.
a)
GRM communication lost, or
no communication to GRM
server.
a)
No connection to the GRM
server.

8. Service

8.1 Service documentation

Service documentation is available on
www.grundfos.com > International website >
WebCAPS > Service.
If you have any questions, please contact the
nearest Grundfos company or service workshop.

9. Disposal

This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
350 mA
max.
Remedy
Replace the CIU 500.
Set the switch to "4".
Check the cable connection
between the Grundfos product and
the CIU 500.
Connect to GRM server and run
the 4-step wizard.
LED1 is flashing green.
Contact the nearest Grundfos
company.
Set the switch to "4".
Check ethernet cable in router.
Check router settings.
Check router related SIM card.
Check that the contract with
Grundfos is valid and there is
access to the GRM data.
Check that you use the lowest
MAC address (lowest number) of
the two ports of CIM 500 (see
sticker on the module) requires a
contract with Grundfos and
granted access to GRM)
Subject to alterations.