PARAMETERS
TP
C
14
Auto reclosing time from partial opening (0 = disabled).
.
.
Blinker output mode:
FP
R
15
0 = fix.
.
.
1 = blinking.
TP
R
16
Pre-flashing time (0 = disabled).
.
.
Courtesy ligth settings:
0 = at the end of the movement for a TC.Y. time.
1 = on if the automation is not closed + TC.Y. time.
FC
Y
17
.
.
2 = on if the courtesy light timer (TC.Y.) is not expired.
3 = open automation light on/off.
4 = open automation light with proportional flashing.
tC
y
18
Courtesy light time.
.
.
Dead-man:
de
a
19
0 = disabled.
.
.
1 = enabled.
Threshold of cycles for assistance request. Once the limit is reached the
se
r
20
next cycles will be done with fast blinking (only if FPr enabled).
.
.
0 = disabled.
Continuous blinking for assistance request (done only with closed
automation):
se
f
21
.
.
0 = disabled.
1 = enabled.
HA
o
22
Water-hammer in opening phase (0 = disabled).
.
.
HA
c
23
Water-hammer in closing phase (0 = disabled).
.
.
Mode of use of the electrical lock:
0 = disabled or not installed.
EL
M
24
1 = enabled without the preventive activation.
.
.
2 = enabled with the preventive activation.
3 = enabled and set as electromagnetic lock.
Mode of use of the R1 output (plug-in):
0 = output not used.
rI
m
25
.
.
1 = electrical lock (copy of the control unit output).
2 = courtesy light (copy of the control unit output).
mp
r
26
Pressure of the motor in closed position, anti-wind function.
.
.
mr
e
27
Function for the mechanical relaxation of the motor.
.
.
EC
o
28
ECOMODE function (0 = disabled).
.
.
SF
t
29
SOFT STOP function (0 = disabled).
.
.
Restore default settings depending on the motor type:
0 = CUSTOM.
1 = XTILUS.
de
f
30
2 = INT VS.
.
.
3 = MINIART.
4 = KINEO 400.
5 = HYPER
tr
s
31
Viewing of the memory location for a single transmitter.
.
.
tr
C
32
Cancellation of a single transmitter.
.
.
Cancelling all transmitters. Enter to modify the parameter and then keep
tr
f
33
pressed the "MENU" button, a count down appears that ends with don on
.
.
the display.
sI
d
34
First coupling between Bluetooth device and control unit.
.
.
NOTE - the parameters highlighted in grey depend on the selected motor. On the table are reported the data of the CUSTOM motor. For more
information, refer to chapter 12.
1.
MODE OF THE SENSOR INTERVENTION Sn.M.
It is possible to select 4 intervention types for the current sensor that detect the motor blocked:
18/24
DESCRIPTION
ITA
ENG
FRA
ESP
DEFAULT
CUSTOM
0
1
0
0
180
0
0
0
0
0
0
0
0
0
0
10
0
TUR
NLD
6-1622420
MIN
MAX
UNIT
0
900
s
0
1
0
10
s
0
4
0
900
s
0
1
x 1000
0
100
cicli
0
1
0
100
x 100ms
0
100
x 100ms
0
3
0
1
0
480
min
0
10
x 50ms
0
1
0
20
x 100ms
0
5
rev.5
14/09/2021