WARNING - in the event of a safety device intervention, the learning is stopped and will appear on the display
Press the "SS" button to start again the learning from the 4th point.
NOTE - if the motors don't stop automatically during the learning, increase the value of the obstacle sensitivity and /or the obstacle sensitivity during
slowdowns (menu SEN and SEL), see paragraph 8, and check that the intervention mode of the current sensor is suitable for the use as limit switch
(menu Sn.M.), see paragraph 9.
11.2 - ADVANCED SETTINGS OF THE STROKE - SINGLE MOTOR
Connect the automation to the MOTOR 1 output and check to have set
the nMT = 1.
Carry out a check of the menus and, if needed, customize the settings before
1.
the learning of the stroke.
Be sure to have set the item menu LSI = P. The slowdowns should be set
during the learning procedure and the amplitudes will be independent in the
two directions.
Unlock the automation and move it to the middle of the stroke.
2.
Press at the same time the "UP" and "MENU" buttons for at least 5 seconds
until the display shows LOP.
If the automation DOESN'T MOVE in opening, press the "DOWN" button to stop
3.
the learning. The display shows L--.
Press the "SS" button to restart the procedure: the automation moves in
opening, at reduced speed.
Reached the opening mechanical stop, the motor stops automatically.
4.
WARNING - if the motor doesn't stop automatically, press the "SS"
button.
In this phase the display shows LOP.
The automation moves automatically in closing, at running speed.
When the automation reaches the position for the beginning of the slowdown,
5.
give a Step-by-Step command (SS).
In this phase the display shows LCL.
The automation proceeds at slowdown speed.
Reached the closing mechanical stop, the motor stops automatically.
6.
WARNING - if the motor doesn't stop automatically, press the "SS"
button.
In this phase the display shows LCL.
The automation moves automatically in opening, at running speed.
When the automation reaches the position for the beginning of the slowdown,
7.
give a Step-by-Step command (SS).
In this phase the display shows LOP.
The automation proceeds at slowdown speed.
Reached the opening mechanical stop, the motor stops automatically.
WARNING - if the motor doesn't stop automatically, press the "SS"
8.
button.
In this phase the display shows LOP.
9.
The automation moves in closing with the slowdowns set.
WARNING - in the event of a safety device intervention, the learning is stopped and will appear on the display
Press the "SS" button to start again the learning from the 4th point.
NOTE - if the motors don't stop automatically during the learning, increase the value of the obstacle sensitivity and /or the obstacle sensitivity during
slowdowns (menu SEN and SEL), see paragraph 8, and check that the intervention mode of the current sensor is suitable for the use as limit switch
(menu Sn.M.), see paragraph 9.
6-1622420
rev.5
ITA
14/09/2021
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
DOWN
MENU
UP
SS
UP
DOWN
UP
MENU
UP
SS
UP
DOWN
MENU
UP
SS
UP
UP
UP
ENG
FRA
ESP
TUR
L--
.
DOWN
DOWN
MENU
MENU
DOWN
MENU
5 seconds
SS
SS
SS
DOWN
DOWN
DOWN
MENU
MENU
MENU
DOWN
MENU
SS
SS
SS
SS
DOWN
DOWN
DOWN
MENU
MENU
MENU
DOWN
MENU
SS
SS
SS
DOWN
SS
MENU
DOWN
MENU
SS
SS
DOWN
MENU
UP
DOWN
MENU
SS
SS
DOWN
MENU
DOWN
MENU
UP
DOWN
SS
MENU
SS
SS
DOWN
UP
DOWN
MENU
MENU
SS
SS
DOWN
MENU
L--
.
SS
DOWN
MENU
SS
DOWN
MENU
NLD
SS
23/24