EB TECHNOLOGY START-S2XL Instrucciones Y Advertencias Para El Instalador página 38

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2
Foreword
This manual provides all the specific information you need to
familiarize yourself with and correctly operate your unit.
Read it very carefully when you purchase the instrument and
consult it whenever you have doubts regarding use and before
performing any maintenance operations.
Safety precautions
Using the unit improperly and performing repairs or modifications
personally will void the warranty.
Nologo declines any responsibility for damages due to
inappropriate use of the product and due to any use other than
the use the product was designed for. Nologo declines any
responsibility for consequential damages
except civil liability for the products.
Environmental protection
measures
Information regarding the environment for customers
within the European Union.
European Directive EC 2002/96 requires that units
bearing this symbol on the unit and/or on the
packaging be disposed of separately from
undifferentiated urban wastes. The symbol
indicates that the product must not be disposed
of with the normal household wastes.
The owner is responsible for disposing of this product and
other electrical and electronic equipment through specific
waste collection facilities indicated by the government or local
public agencies. Correct disposal and recycling help prevent
any potentially negative impact on the environment and human
health. To receive more detailed information regarding disposal
of your unit, we recommend that you contact the competent
public agencies, the waste collection service or the shop where
you purchased the product.
Small dictionary
START
START control
Vac
(alternate current)
Vdc
(direct current)
FCA or FCO
Opening Limit Switch
FCC
Closing Limit Switch
NC
Normally closed
NA
Normally open
Contatto pulito
Isolated contact
1
230 Vac NEUTRAL
EARTH
2
2
3
0
V
a
c
P
H
A
S
E
3
LIGHT 230 Vac
4
LIGHT 230 Vac
5
MOTOR COMMON
MOTOR OPEN
6
MOTOR CLOSE
7
CONTACT FLASH / SPY
8
9
CONTACT FLASH / SPY
10
12 Vac 200mA
12 Vac 200mA
11
12
FCA OPEN MOTOR
13
FCC CLOSE MOTOR
14
STOP
PHOTO-A / CLOSING
15
16
OPEN / START
CLOSE
17
18
BUS-DATA
19
COMMON
20
- NEGATIVE ANTENNA
21
+ POSITIVE ANTENNA

Publicidad

Tabla de contenido
loading

Tabla de contenido