EB TECHNOLOGY START-S2XL Instrucciones Y Advertencias Para El Instalador página 45

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.02 Remote controls: memorization of the codes
The control unit dispose of a button PULSANTE P1 to program the worling time and to memorize the code of the
remote controls. If you use a new FIXED CODE remote control like SMILE-C, make sure that all butoons have a
code otherwise you need to create a code.
In case of a SMILE-H ( rolling code remote control) you don't need to do the above mentioned procedure.
The output of the control unit should be deactivated, so no contacts available, the lights should be turned off.
This operation is possible only when the gate is closed. The LED L1 should flash regularly,
see " Codes managing" in the previous paragraph.
To memorize the first channel of the remote control with the control OPEN ( START) .
This works with the logic DIP B 1 and 2 see " Function logic".
Press and release the button PULSANTE P1 in the control unit, LED L1 will lit for 6 seconds.
1
Then
In this 6 seconds push the button of the remote control which is associated to the contorl OPEN (START),
we suggest the 1st channel.
2
To confirm the right operation LED L1 will flash for 5 times and then regularly as at the beginning.
The control OPEN has been memorized
To memorize the control " CLOSE" in the second channel
This operation is possible only in this sequence: CLOSE-STOP-CLOSE which it cannot be changed.
1
Press and release the button PULSANTE P1 in the control board, LED L1 will li tfor 6 seconds. Then
2
In these 6 seconds press and release the button PULSANTE P1 again, LED L1 will lit for 6 seconds. Then
In these seconds press the button of the remote control which should be associated to the control
CLOSE, we suggest the 2nd channel. This function is only possible in this sequence:
3
CLOSE-STOP-CLOSE and it cannot be changed.
To confirm the right procedure LED L1 will flash for 5 times and then regularly as at the beginning.
The code CLOSE has been memorized.
If LED L1 will not flash immediately for 5 times, it means that the memory is full and it cannot accept other codes.
Concerning the 20bit codes, the memory can learn maximum 22 different codes, if you need to learn more codes
we suggest you to put an additional receiver RX2 or RX4 with a capacity of 200/3000 codes.
If you are not sure that the memorization has been correctly start from point no.1 but before cancel the previous codes
in the receiver. See previous chapter " cancellation of the memory"
9

Publicidad

Tabla de contenido
loading