6
2.00 Connection of the motor
Pay attention not to invert the poles OPEN and CLOSE.
In case of doubts, put the gate manually in the middle.
Be ready to stop the gate with a STOP control.
Make sure that the control OPEN is really OPEN,
try to interrupt the photo-beams:if the gate starts closing,
the connection is not correct and you need to reverse the cables OPEN and CLOSE of the motor
Please note that you can hear the relay even if it is not connected,
while opening it sounds very fast, while closing it sounds very slowly.
2.01 Connection of the signal light or lamp
3
4
5
6
7
Connect the lamp LUCE -1 230vAC with flashing card.
Or a lamp with fix light when the gate is moving.
For courtesy light see paragraph 4.02 .
2.02 Connection of the photocell FOTO-A inverting only when closing
The contact of the receiver of the photo-beam should be :
- Isolated from power tensions
- NORMALLY CLOSED
If you use more couples of photo-beams,
the connections should be serial.
The photo-beams interfere only when closing
provoking a total inversion.
If the input FOTO is not used, put the DIP 4
in ON and exclude FOTO in the DIPA
2.03 Connection of the STOP with immediately intervention
BUTTON: stop and forbit for a while the function of the control unit
until a new control.
SWITCH: keep the gate closed until a new control.
The connections of the safety devices prevue any
button or a normally closed contact .
In case of more safety devices, connect in serial.
If the input STOP is not used,
put the DIP 3 in ON and exclude STOP in the DIPA
3
Lamp
Connect the lamp LUCE -0230 without flashing card.
21
21
3
4
5
6
7
20
19
18
17
16
15
14
20
19
18
17
16
15
14
4
5
6
7
CLOSE
OPEN
COMMON
8
9
13
12
11
10
13
12
11
10

Publicidad

Tabla de contenido
loading

Tabla de contenido