10 Supplement
10 Supplement
10.1 Technical data
Note for approved instruments
The technical data in the respective safety instructions which are included in delivery are valid for
approved instruments (e.g. with Ex approval). These data can differ from the data listed herein, for
example regarding the process conditions or the voltage supply.
All approval documents can be downloaded from our homepage.
Materials and weights
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
Ʋ Sensor tip
Ʋ Device seal - Standard version
Ʋ Device seal - Hygienic version
Ʋ Process seal
Ʋ Process fittings
Materials, non-wetted parts
Ʋ Housing
Ʋ Device seal - Hygienic design AC and
AM
10)
Weight
General data
Process fittings
Ʋ Pipe thread for hygienic threaded
adapter (ISO 228-1)
Ʋ Pipe thread, conical (ASME B1.20.1)
Max. torque - process fitting
Ʋ Thread G½, ½ NPT
Ʋ Hygienic adapter
Surface quality
Measurement accuracy
Hysteresis
Switching delay
Ambient conditions
Ambient temperature on the housing
Storage and transport temperature
Relative humidity
not in contact with the medium
10)
26
PEEK, polished
FKM
EPDM
Klingersil C-4400
316L
316L and plastic (Polycarbonate)
EPDM
approx. 200 g (0.441 lbs)
G½
½ NPT
50 Nm (37 lbf ft)
20 Nm (15 lbf ft)
R
< 0.76 µm (3.00
in)
-5
a
approx. 1 mm (0.04 in)
approx. 500 ms (on/off)
-40 ... +70 °C (-40 ... +158 °F)
-40 ... +80 °C (-40 ... +176 °F)
20 ... 85 %
LFC • Transistor (PNP)