Switch-On Phase; Setup; Indication Of The Switching Status; Function Table - SICK LFC Manual De Instrucciones

Ocultar thumbs Ver también para LFC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

M12 x 1 plug
2
1
3
4
Abb. 17: Wiring plan M12 x 1 plug - Transistor output,
three-wire
1
Voltage supply
2
PNP switching
Contact, plug con-
nector
1
2
3
4
5.4

Switch-on phase

After switching on, the device first carries out a
self-check.
The current measured value is then output on
the signal cable.
6

Setup

6.1
Indication of the switching
status
The switching status of the electronics can be
checked via the 360° status indication (LEDs)
integrated in the upper part of the housing.
The colours of the 360° status indication have
the following meaning:
Green lights up - power supply connected,
sensor output high-impedance
Green flashing - Maintenance required
Yellow lights up - power supply connected,
sensor output low impedance
Red lights - shortcircuit or overload in the
load circuit (sensor output high-impedance)
Red flashing - Error at sensor or electronics
(sensor output high impedance) or device is
in simulation
Default setting
6)
Default setting
7)
Default setting
8)
Output 1
9)
LFC • Transistor (PNP)
+
1
out 2
out 1
2
2
-
Function/Polarity
Voltage supply/+
Transistor output 2
Voltage supply/-
Transistor output 1
6)
6.2

Function table

The following table provides an overview of
the switching conditions depending on the set
mode and the level (factory setting).
Coverage
Switching
status
7)
Output 1
Covered
open
Uncovered
closed
Covered/
open
Uncovered
7

Diagnostics and servicing

7.1

Maintenance

Maintenance
If the device is used properly, no special mainte-
nance is required in normal operation.
Cleaning
The cleaning helps that the type label and mar-
kings on the instrument are visible.
Take note of the following:
Use only cleaning agents which do not cor-
rode the housings, type label and seals
Use only cleaning methods corresponding
to the housing protection rating
7.2

Rectify faults

Reaction when malfunction occurs
The operator of the system is responsible for
taking suitable measures to rectify faults.
Causes of malfunction
The device offers maximum reliability. Never-
theless, faults can occur during operation.
These may be caused by the following, e.g.:
6 Setup
Switching
Control
status
lamp
8)
9)
Output 2
closed
Green
open
Yellow
open
Red
23

Publicidad

Tabla de contenido
loading

Tabla de contenido