SYSTEM INTERFACE

General information

On the upper left area of the display, the status of the
workshop's air supply valve (GENERAL AIR) is displayed:
GENERAL AIR ON: the compressed air supply is enabled.
GENERAL AIR OFF: the compressed air supply is disabled.
QUICK INFORMATION MENU
Access to quick information menu
When the unit is in standby mode (the switch key is in
"normal" position), relevant data about the tank's status
and configuration can be displayed by pressing the "left"
(for CH1) or "right" (for CH2) key.
Available information
The information displayed will vary depending on whether
the tank is using analog or digital probes. For tanks with
analog probe, it will display:
- Tank number and assigned channel.
- Product name.
- Probe height (in centimeters).
- Fluid density (in Kg/m3).
- Tank capacity (in liters or gallons).
- Warning level (in liters or gallons).
- Stop level (in liters or gallons).

SYSTEM MENU

To gain access to the main menu, insert the bypass key
into the unit and switch from normal position
bypass position
.
The main menu will appear on screen:
CAUTION!: while the unit is in bypass mode, both the
general air supply and the pump control valves will be
permanently activated regardless of the system's logic setup.
The arrow at the left side of the screen indicates the
currently selected option. Use the "up" and "down" keys
on the keypad to select the desired option and press "OK"
to confirm.
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
On the upper right area of the display, the protocol
employed for connecting the U·tank to the NEX-U
network is displayed. Currently, only CAN-BUS connection
is available.
For tanks without analog probe, it will display:
- Tank number and assigned channel.
- Product name.
- Tank capacity (in liters or gallons).
- A message indicating whether the tank is
using contactprobes, or not using any level
monitoring procedure at all ("TANK LEVEL OFF").
To go back to the standby screen, press the