INSTALL FLUE MOUNTING
BRACKET
DUCTED AND NON-DUCTED
1. Assemble the fl ue mounting bracket, adju-
sting outside width as shown. (Fig.12)
2. Carefully center the mounting bracket
directly over the range hood location.
3. Secure the bracket assembly to the cei-
ling
using (2) 4.8 x 38mm mounting
screws and drywall anchors (Fig.13). Make
sure the bracket is pushed into the corner,
tight against the wall if necessary, and cente-
red over the hood. Complete the installation.
DUCTED INSTALLATION ONLY
Note: Rooms with 10 or 11 foot ceil-
ings require fl ue extension model
AEWPP9SB, available from your local
dealer. Discard the upper fl ue supplied
with the range hood and replace it with
the longer fl ue extension.
1. Attach ductwork to damper/duct connector.
2. Run 8" WPPIQ or 10" WPPIQT & WPPE
diameter metal ductwork to the outside
location (Fig.14).
3. Install an appropriate wall or roof cap with
damper to exhaust the air to the outside.
4. Tape all duct joints with aluminum duct tape.
5. Tape all openings on top surface of range
hood (Fig.15).
6. Install upper and lower decorative fl ues
onto the range hood. Vents are concealed
on 8-foot ceilings. Vents maybe exposed
on 9-foot ceilings (Fig.16).
FIG. 15
- 12 -
MOUNTING SCREWS
(3,9x9,5mm Pan Head)
DRYWALL
ANCHORS
MOUNTING SCREWS
(4,8x38mm)
DECORATIVE
8" or 10" ROUND
CEILING
CONCEALED
VENTS
FIG. 12
FIG. 13
FLUE
DUCT TAPE
METAL DUCT
FIG. 14
FIG. 16