Best WPP9 Manual De Instrucciones página 16

Ocultar thumbs Ver también para WPP9:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WPP9 Programming Mode Procedure
WPP9E Programming Mode Procedure
The range hood is designed to work with several diff erent blowers models. Before using the
hood, the control must fi rst be programmed to your blower model, in order to achieve proper
operating speed:
1. Find the SETUP number that corresponds to the blower model that is installed with your
range hood.
2. There must be power to the hood but the blower and lights must be turned off .
3. Push simultaneously LIGHT SWITCH and RESET SWITCH for 5 sec: the display shows a
"P" blinking three times and then shows alternately the "P" and the setup selected.
4.Select the desired setup with BLOWER SWITCH (3
(1
2
3).
5. Push TIMER SWITCH to confi rm.
6. The display ("P") blinks two times ( 2 sec on - 0,5sec off ) recording the selected setup.
Description of "Speed Level"
Setup 1 is for motors with a rating
up to 3.0 amp
Setup 2 is for motors with a rating
between 3.1 amp and 5.0 amp
Setup 3 is for motors with a rating
greater than 5.1 to 6 amp
2
1) or RESET SWITCH
- 16 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wpp9iq

Tabla de contenido