7. Secure upper fl ue to fl ue mounting bracket
with (2) 3.9 x 6mm screws (Fig.17).
NON-DUCTED INSTALLATION AVAILABLE
ONLY FOR SINGLE BLOWER VERSION
(WPP9IQ only)
Note:
a. Purchase Model ANKWPP9 Non-ducted
Recirculation Kit from your local dealer.
b. Rooms with 10 or 11 foot ceilings require
Flue Extension Model AEWPP9SBN,
available from your local dealer. Discard
the upper flue supplied with the range
hood and replace it with the longer fl ue
extension.
1. Attach the 6"-to-8" adapter to blower
discharge and tape joint with aluminum
duct tape (Fig.18).
2. Tape all openings on top surface of range
hood (Fig.15).
3. Install the plenum to the upper decorative
fl ue using (4) 3.9 x 6mm fl at head screws
provided as shown (Fig.19).
4. Attach 6" expandable ducting to the plenum
using the adapter and tape joints with
aluminum duct tape (Fig.20).
5. Slide upper fl ue into lower fl ue.
6. Attach fl ue assembly to hood.
7. Attach fl ex duct to plenum through the duct
connector (Fig.20).
8. Attach upper fl ue to fl ue bracket using (2)
3.9 x 6mm fl at head screws.
MOUNTING SCREWS
(3,9x6mm Flat Head)
FIG. 19
- 13 -
DUCT CON-
NECTOR
FIG. 17
FIG. 18
FIG. 20