Electrical Connection - Fagor CFI-4GLSTANAT Manual De Instalación Y Utilizacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1/ INSTALLING YOUR APPLIANCE

• ELECTRICAL CONNECTION

Your hob (which is supplied with an H05V2V2-
F type wire) must be connected to the 220-
240 V ~ single phase grid via a standardised
CEI 60083 2-pole + ground electrical outlet
plug or an all-pole cut-off device, in
compliance with the current regulations.
The electrical plug socket must remain
accessible after installation.
T
YPE OF CABLE SECTION TO BE USED
H05V2V2F -T90 cable
Ref. After-sales
service: 77x9060
Conductor section
in mm
2
Fuse
220-240 V ~ - 50 Hz
3 conductors
including
1 ground
1
10 A
Warning
The safety wire (green/yellow) is
connected to the appliance's ground terminal
and must be connected to the installation's
ground terminal
be used in the installation. If the power cable is
damaged, it must be replaced by a cable or a
special kit which is available from the
manufacturer or their After-Sales Service
Department.
Tip
Using a gas cooking appliance generates
heat and humidity in its local vicinity. Make sure
that your kitchen is well-ventilated: ensure
natural ventilation openings in your home are
unobstructed or install a mechanical ventilation
device (mechanical ventilation hood). Intensive,
prolonged use of the appliance may require
additional ventilation; you can, for example,
open a window or provide more effective
ventilation by increasing the setting on a
mechanical ventilation system, where installed.
(a minimum air flow of 2 m
power is required).
For example : 30 cm - 2 gas burners
Total power : 1.5 + 3.1 = 4.6 kW
4.6 kW x 2 = 9.2 m
minimum flow.
9
. A 10 amperes fuse must
3
/hr per kW of gas
/h
3
EN

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido