H.0
Selección consigna analógica
Tabla 1
Valor / Value
Valor / Value
Valor / Value
Valor / Value
0
0
0
0
1
1
1
1
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
4
5
5
5
5
5
5
6
6
6
6
7
7
7
7
8
8
8
8
9
9
9
9
10
10
10
10
11
11
11
11
X = con puente J1 soldado (ver página 17)
REF y REF2 se seleccionan mediante el parámetro H.1. Existe la
posibilidad de invertir las entradas. La tabla 2 indica los valores
para H.1.
H.1
Inversión consigna analógica
Tabla 2
Valor
Valor
Valor
Consigna activada
Consigna activada
Consigna activada
0
0
0
REF/REF1
REF/REF1
REF/REF1
1
1
REF/REF1
REF/REF1
2
2
2
REF2
REF2
REF2
3
3
3
REF2
REF2
REF2
La tensión ±10 V de la entrada REF1 (borne 8) se suma algebrai-
camente a la tensión dada en REF. Se consigue f máx. añadiendo
±10 V.
o.13 =
H.0
=
�� �
���
� �
�� �
� �
��� �
�� �
��� �
����
������
������
����
24
REF
REF
REF
REF
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
}
}
}
}
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
o.13 = "4"
o.13 = "4"
o.13 = "4"
o.13 = "4"
o.13 = "4"
o.13 = "4"
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
± 10 V
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
Lógica
Lógica
Lógica
no invertida
no invertida
no invertida
invertida
no invertida
no invertida
no invertida
invertida
invertida
invertida
Regleta / Terminal Strip
o.13 =
0 ... 10 V
H.0
El sentido de giro depende de la selección realizada sobre la
regleta.
H.0
Presetting mode reference value
Table 1
REF2
REF2
REF2
REF2
0...10 V
0...10 V
0...10 V
0...10 V
0...20 mA
0...20 mA
0...20 mA
0...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...10 V
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
0...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
0...10 V
0...10 V
0...10 V
0...10 V
0...20 mA
0...20 mA
0...20 mA
0...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
0...10 V
0...10 V
0...10 V
0...10 V
0...20 mA
0...20 mA
0...20 mA
0...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
X = Jumper soldered in (see page 17)
REF and REF2 are selected with the parameter H.1. It is possible
to invert the inputs. Table 2 shows possible values for H.1.
H.1
Logic of analog inputs
Table 2
Value
Value
Value
Active Set Value Input
Active Set Value Input
Active Set Value Input
0
0
0
REF
REF
REF
1
1
1
REF
REF
REF
2
2
2
REF2
REF2
REF2
3
3
3
REF2
REF2
REF2
The ±10 V input REF1 (terminal 8) is added sign-correct to the
REF input. f
is attained at a sum of ±10 V.
max
Regleta / Terminal Strip
=
0 ... ±10 V
Puente J1/Jumper 1
Puente J1/Jumper 1
Puente J1/Jumper 1
Puente J1/Jumper 1
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Logic
Logic
Logic
not inverted
not inverted
not inverted
inverted
inverted
inverted
not inverted
not inverted
not inverted
inverted
inverted
inverted
o.13 =
±Regleta/±Terminal Strip
H.0
=
0 ... ±10 V
El sentido de giro depende de la polaridad de la con-
signa.