Descargar Imprimir esta página

cinetto B-moved PS40.3 Instrucciones De Ensamblaje página 54

Ocultar thumbs Ver también para B-moved PS40.3:

Publicidad

During the self-learning cycle the pairing with the remote control is not working.
If the self-learning cycle is not working, because of lack if electricity or for the presence of obstacles disconnect from the
power supply, close manually the doors and start the self-learning cycle again.
4 Pairing of the remote control
To start this function press and release the "REMOTE
SET" button on the power unit. After the pressure,
a red LED will start blinking on the control
unit. During the blinking press for at
least 3 seconds one of the buttons on
the remote control.
Using more control units with
a single remote control is al-
lowed.
Using more remote controls
with a single control unit is al-
lowed.
Do not pair the remote control to the
power unit during the self-learning
cycle.
5 Wiring of the switch on the control unit
DEVICE = 0 - 48V
The N.O. switch is a normally-opened electric contact, managed by the control unit.
There is no electric tension on the terminals of the switch. The switch isn't a voltage
supply.
MAX 2A
The switch can manage devices with nominal tension between 0 and 48V
and a maximum electric current of 2A.
The wiring between the switch and the devices must be performed by spe-
cialized personnel according to the following scheme.
SET
00:00:03
FREQUENCY: 433,92 MHZ
MAX POWER: 1 mW

Publicidad

loading