Setup
Network configuration: 240 V split phase
DIP switch S21: OFF
DIP switch S22: ON
Network configuration: Wye 208 V
Detail: Two of the three connected
phases are used
DIP switch S21: ON
DIP switch S22: ON
Network configuration: not assigned
Detail: Switch combinations that are not
permitted
1. For connection variant Delta High Leg, the switch should be set as follows: OFF/OFF (single phase) for connection to L1 - N/GND and L2 - N/GND, and ON/OFF (split phase)
for connection to L1 - L2.
20
Setup
1
Vehicle charging and supply cables
Information on vehicle charging cables
and plugs
Different vehicle charge ports
A
are available depending on country-specific vehicle
equipment.
IEC 62196-2/
SAE-J1772-2009
Type 1 UL/IEC
IEC 62196-2/
SAE-J1772-2009
Type 1
IEC 62196-2
Type 2
GB/T 20234.2
Type GB
Commissioning and configuration
Getting started
Configure the following settings before using the
charger for the first time.
Information
and vehicle plugs
B
−
Options marked Skip can be skipped. A setting is
not configured in this case.
−
Settings can always be changed on the display
( ).
e
Switch on the charger by pressing the Power
button.
In the display, the control panel for the fur-
ther setup of the device appears.
g Refer to chapter "Operating instructions" on
page 24.
Language and country
1. Select a language from the list. Confirm your
selection.
2. Select a country from the list.
3. Confirm the selected language and country.
Data transmission
e
Read and confirm instructions for transmitting
data.