Keypad Buttons; Job - Stanley Tau Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Tau Controller
The left column shows the currently defined Tau Controller settings and menu choices. The
Options Screen column shows options for each selection. Screen navigation options appear above
each screen.
Default Screens
NOTE:
Programming changes are stored after exiting current menu and returning to run screen.

2.7.1 Keypad Buttons

2.7.1.1 Job

Job programs the torque window for the tool strategy and controls tool operation for tightening a
fastener with one TC/AM (Torque Control, Angle Monitoring) Step. Jobs are required to run a
tool strategy. Inputs or the tool MFB are used to select specific Jobs with different tool strategies.
Program Job parameters according to the integration and tool strategy desired. The Tau can have a
maximum of two Jobs.
Job Screens
Torque Bajo – The minimum peak torque for an acceptable tightening cycle (required). If the
actual torque does not reach this limit, the tightening cycle is flagged as NOK and the yellow
Programación
Selects option for data input, accepts
Toggle Button
changes.
Select by pressing the Job button on the
keypad.
Use the left/right arrow keys to select a job
for programming.
Torque objetivo – The torque at which the
controller shuts off the tool (required for this
step). Should be greater than Torque bajo and
lower than Torque alto.
Torque Alto – The maximum peak torque for
an acceptable tightening cycle, required. If the
actual torque exceeds this limit, the tightening
cycle will be flagged as NOK and the red
LED on the front panel and tool illuminates.
Value must be greater than Torque objetivo,
but less than or equal to the rated torque
marked on the tool.
Options Screen
Options Screens
13

Publicidad

Tabla de contenido
loading

Tabla de contenido