ATC – Enables the Adaptive Tightening Control algorithm to slow the tool speed as the torque
rises.
The default values can be modified for when the algorithm starts (%Torque para inicio ATC),
when it ends (%Torque para final ATC) and what the tool speed is after the algorithm ends
(%de velocidad final ATC). The torque units are percent of Target Torque. The speed values
are percent of Velocidad.
Disassembly Velocidad – The speed of the tool during (Reverse) operation in RPM (revolutions
per minute).
Disassembly Acceleration – The rate the tool gets up to Disassembly Velocidad in RPM/s
(revolutions per minute per second).
Preset Parameters (Non-editable)
(Soft Stop) – This controls how the tool is turned off AFTER reaching target torque. This is
designed as an ergonomic benefit to ease operator discomfort with direct-drive tools. The tools
current will be removed for five msec, reapplied for 25 msec, then it will ramp to zero over 75
msec.
(Power) – The maximum power available to the tool to perform the tightening. Permanently set
at 100 percent of maximum rated torque of the tool.
Press a keypad button to save changes and return to the Run screen.

2.7.1.4 Inputs and Outputs (E/S)

E/S programs the Entrada y salida functions of the controller. A complete list of available E/S
elements and their descriptions is available in Section 4.2.
E/S Screens
Press a keypad button to save changes and return to the Run screen.
16
Options Screen
Press the E/S button on the keypad to select.
See Section 4.2.2 for a description of the
OK/NOK tipo salida parameters.
See Section 4.2.1 for a description of the
Latch Start Input parameter.