8. INSTALLATION

WARNING!
Refer to Safety chapters.
8.1 Positioning
This appliance can be installed in a dry,
well ventilated indoor where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Climate
class
SN
N
ST
T
Some functional problems
might occur for some types
of models when operating
outside of that range. The
correct operation can only
be guaranteed within the
specified temperature range.
If you have any doubts
regarding where to install the
appliance, please turn to the
vendor, to our customer
service or to the nearest
Authorised Service Centre.
Ambient temperature
+10°C to + 32°C
+16°C to + 32°C
+16°C to + 38°C
+16°C to + 43°C

7.3 Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer
to "Installation".
3. If necessary, replace the defective
door gaskets. Contact the Authorised
Service Centre.
8.2 Electrical connection
• Before plugging in, ensure that the
voltage and frequency shown on the
rating plate correspond to your
domestic power supply.
• The appliance must be earthed. The
power supply cable plug is provided
with a contact for this purpose. If the
domestic power supply socket is not
earthed, connect the appliance to a
separate earth in compliance with
current regulations, consulting a
qualified electrician.
• The manufacturer declines all
responsibility if the above safety
precautions are not observed.
• This appliance complies with the
E.E.C. Directives.

8.3 Height adjustment

The height of the appliance is adjustable
from 820 to 870 mm to fine up with
existing kitchen units.

Publicidad