Mounting; Electrical Installation - SICK WLG16 Instrucciones De Operación

Ocultar thumbs Ver también para WLG16:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
4

Mounting

5

Electrical installation

8020349.19RH / 22.12.2020 | SICK
Subject to change without notice
Press-turn element: adjustment of mode and sensitivity
2
LED indicator yellow: status of received light beam
3
LED indicator green: supply voltage active
4
Press-turn element: time function adjustment
5
Teach pushbutton: adjustment of light/dark switching
6
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Note pin assignment.
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations on connection diagram:
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
Table 1: Connections
Wxx16x-
x4
1 = BN
4
2 = WH
3 = BU
4 = BK
5= GY
1
Wxx16x-
1 = BN
2 = BU
3 = not connected
4 = BK
5= WH
6 = GY
7 = not connected
xH
3
4
0.14 mm
2
AWG26
2
1
x9
1
6
2
5
3
4
I
= 4 A
N
MOUNTING
x5
xI
5
3
0.14 mm
2
AWG26
2
xB
7
1
6
2
5
3
4
I
= 6 A
N
4
5

Publicidad

Tabla de contenido
loading

Tabla de contenido