6.2. Output
Pin
Function
1
COM 0VDC
2
SINGLE OK
3
SINGLE NOK
4
CYCLE OK
5
CYCLE NOK
6
TOTAL END
7
LEVER
8
MOTOR ON
9
STOP TIME
10
REV TIME
11
FAILURE
12
NOT USED
Max. on outputs: 24V-20mA, max 0.5W.
The output signals are protected.
An overload or a short circuit on the
signals triggers the controller to stop. To
reset the signals, you must turn off the
controller for a minimum of 6 seconds,
check the connectors and then start up
again.
05/2020
Comment
Common earth for all Outputs
Correct screwing done between min and max time.
Signal starts when the screwing is done and it resets when the lever is
pressed to start a new one
Incorrect screwing done under min time or over max time.
Signal starts at the end of the screwing and it resets when the lever is
pressed to start a new one.
Cycle done well not exceeding the pre-set reject screws.
Signal starts at the end of the cycle and it resets a new one starts
Incorrect cycle where in one or more screws the pre-set rejected screws
have been gone over.
Signal starts at the end of the cycle and it resets a new one starts.
End of cycle or of sequence.
Signal starts at the end of the cycle and it resets a new one starts.
Signal starts when the lever is pressed or at input start and it stops when it
is released
Signal starts when the motor starts and it switches off when the motor
stops.
Signal starts when the screwing exceeds the max time (see also MAX
TIME). It resets when the lever is pressed to start a new screwing.
This option is useful to a NOK screw which has reached the torque over
the max time.
It's also useful when a tool is used with a stop time and not after the torque
reached.
Signal starts if REV TM is on when the unscrewing cycle is over.
Signal ends when the lever is pressed for a new cycle.
Signal starts at any error detected by the unit (see Trouble Shooting).
Not Used.