7 Technical data
7.1 Festo module carrier
Electrical/mechanical specifications
Operating voltage
Input current
Output voltage
Output current
Fuse
Mains connection
Overvoltage category
Protection class
Signal connection
Front-plate width, power supply
Size 1
Range of application
Operating height
Ambient temperature
Rel. air humidity
Contamination level
CE marking
Subject to change
Radio interference
The device includes components which are intended for industrial environments. These
can lead to radio interference in non-industrial environments.
Remove the device from operation in the case of disturbances from third parties.
© Festo Didactic 8137259
EduTrainer Network and Security – Operating Instructions
120 V – 230 V AC ±10%
50 ... 60 Hz
1.3 A ... 0.65 A AC
24 V DC ± 3%, safe low voltage
Max. 4.0 A
Micro fuse, 5x20mm, 3.15 A, slow-blow
Detachable mains supply line IEC 60320, C13
CAT II, operation on the building's wiring system
I, operation with PE conductor
4 mm safety sockets
3-pin plug for internal supply to modules
6 HP (1 HP = 1/5" = 5.08 mm)
297 mm x 305 mm x 120 mm (60 modules)
Only indoors
Up to 2000 m above NN (sea level)
5 ... 40°C
<= 80% up to 31° C
2, dry, non-conductive contamination
In accordance with low voltage directive
In accordance with EMC directive
In accordance with RoHS directive
WARNING