Technical Data; General Specifications; Fault Switches - Festo 8111819 Descripción Resumida

Conjunto de сomponentes сircuitos básicos de la eléctrica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Component Set Basic Electrical Circuits

6 Technical data

6.1 General specifications

Parameter
Operating voltage of components
Electrical connection
Short circuit
Dimensions
CE marking per
Subject to change
Note:
For a detailed description of the components, see the chapter "Brief description of components"

6.2 Fault switches

Note:
Some parts in this components set contain a fault switch by means of which operation of the
component can be interrupted with a fault. This enables realistic fault finding in circuits that are set
up.
Activating the fault switch
26
Value
12 V ... 15V DC, 0.8 A
4 mm / 2 mm safety plug/detent 19 mm
The components are not resistant to short-circuits and
may only be operated via a power supply with limited
power.
35.5 mm x 37.3 mm x 49.2 mm
RoHS directive
The fault switch is operated via a small screwdriver,
which is inserted into the housing next to the safety
bushings.
© Festo Didactic 8111817