Section 3: Operation

Site Prep Verification

It is important that the generator is installed in such a way
that the airflow into and out of the generator is not
impeded. Verify that all shrubs or tall grasses have been
removed within 3 ft. (0.91 m) of the intake and discharge
louvers on the sides of the enclosure. It is also important
that the generator is not subject to water intrusion. Verify
that all potential sources such as water sprinklers, roof
run-off, rain gutter down spouts and sump pump
discharges are directed away from the generator
enclosure.
WARNING
Risk of fire. Keep air inlet and exhaust areas
free from leaves, grass, snow and other debris.
Failure to do so could result in death, serious injury,
property, and equipment damage.
DANGER
Automatic start-up. Disconnect utility power and
render unit inoperable before working on unit.
Failure to do so will result in death or serious injury.
Turn the generator OFF before performing maintenance.
Remove 7.5 Amp fuse, T1 and T2 battery charge fuses,
and disconnect battery cables to prevent accidental start
up. Disconnect the NEGATIVE (-) cable first, then
disconnect the POSITIVE (+) cable. When connecting
the cables, connect the POSITIVE cable first, the
NEGATIVE cable last.
WARNING

Side Compartment

Local codes may require that the side compartment be
locked. A hasp is provided so the owner/operator can
secure the side compartment with a padlock. Check local
codes for side compartment locking requirements.
Owner's Manual for 60 Hz Synergy Generator™
B
Figure 3-1. Open Side Compartment

Main Circuit Breaker (Generator Disconnect)

This is a 2-pole breaker rated according to relevant
specifications. See "A" in

LED Indicator Lights

See "B" in
(000251)
Green LED "Ready" light is on when utility is
present and the control panel button is in the AUTO
position. This also indicates when the generator is
running.
Red LED "Alarm" light is on when the generator is
OFF or a fault is detected. Contact an Independent
(000191)
Authorized Servicing Dealer.
Yellow LED "Maintenance" light.
NOTE: Yellow LED may be on at the same time as either
the Red or Green LED.
120V GFCI Outlet/15 Amp
Breaker
See "C" in
Figure
external 15 Amp, 120 volt GFCI convenience outlet
located in the top corner of the compartment.
When the generator is running in the absence of utility
power, this outlet may also be used to power items
(000182)
outside the home such as lights or power tools. This
outlet may also be used when utility power is present by
running the generator in manual mode.
This outlet does not provide power if the generator is not
running. Do not use this outlet when the generator is in
Exercise mode. This outlet is protected by a 15 Amp
circuit breaker in the side compartment.
C
Figure
3-1.
Figure
3-1.
3-1. This generator is equipped with an
Operation
000931
A
11