Australia Fuel Field Install Kit
Figure 3-10.
Wire
From-Connection
Number
1
Female Fast-On (14-16 Gauge)
[Wires 16 & 1 intertwined]
2
Female Fast-On (18-20 Gauge)
3
Female Fast-On (18-20 Gauge)
4
Male Fast-On (18-20 Gauge)
5
Female Fast-On (18-20 Gauge)
6
Female Fast-On (18-20 Gauge)
7
Female Fast-On (18-20 Gauge)
8
1/4" Strip
9
Female Fast-On (18-20 Gauge)
10
Ring Terminal (18-20 Gauge)
11
¼ inch strip
12
¼ inch strip
13
¼ inch strip
14
¼ inch strip
15
Female Fast-On (18-20 Gauge)
16
¼ inch strip
17
¼ inch strip
16
Table 3-2. Wire Gauge and Length Chart
Female Fast-On (14-16 Gauge)
[Wires 4 & 1A intertwined]
Female Fast-On (18-20 Gauge)
Female Fast-On (18-20 Gauge)
Female Fast-On (14-16 Gauge)
[Wires 4 & 1 intertwined]
Butt Splice 2 end A (14-16 Gauge)
[Wires 5 & 6 intertwined]
Butt Splice 2 end A (14-16 Gauge)
[Wires 5 & 6 intertwined]
Female Fast-On (18-20 Gauge)
Ring Terminal (18-20 Gauge)
½ inch strip folded over in half. Butt Splice 1 end A
Butt Splice 2 end B (14-16 Gauge)
[Wires 15 & 11 intertwined]
Butt Splice 1 end B (14-16 AWG)
[Wires 12 & 13 intertwined]
Butt Splice 1 end B (14-16 AWG)
[Wires 12 & 13 intertwined]
Female Fast-On (18-20 AWG)
Butt Splice 2 end B (14-16 AWG)
[Wires 15 & 11 intertwined]
Female Fast-On (18-20 Gauge)
[Wires 16&1 intertwined]
Ring Terminal (18-20 Gauge)
Verify all connections per wiring diagram
11.
Reconnect all power, set timer, and program the
12.
gas pressure switch to proper setting for desired
fuel type. Instructions can be found in the gas pres-
sure switch manual.
To-Connection
1/4" Strip
(14-16 Gauge)
Installation Addendum For 50 Hz Air-cooled Generators
Wire Length
12"
12"
20"
20"
12"
12"
60"
60"
12"
12"
12"
6"
6"
30"
60"
12"
60" (Green/Yellow wire)