Parameter
Gas pre-flow time
Starting current
Starting current-time
Hot start
Hot start-time
Current rise (upslope)
Secondary current I
2
(% of secondary current I
Pulse frequency
Pulse duty cycle
(% of secondary current I
Current reduction (downslope)
Final current
Final current-time
Gas post-flow time
(in % dependent on the welding
current)
at 100 % the following apply
3 A
-->
2 sec.
50 A
-->
3.5 sec.
100 A
-->
5.1 sec.
140 A
-->
6.4 sec.
180 A
-->
7.7 sec.
HF arc striking
26
Code
)
1
)
1
Standard
Adjustment
value
range
0.1 s
0.1...10 s
50 %
5...200 %
0.1 s
0.0...20 s
125 %
5...200 %
1.0 s
0.0...20 s
5 %
0...99 %
50 %
1...200 %
5.0 Hz
0.2...500 Hz
50 %
1...99 %
20 %
0...99 %
25 %
5...200 %
0.2 s
0...20 s
100 %
20...500 %
OFF
OFF...On
Mode
WIG
WIG
Electrode
2-cycle
4-cycle
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x