Electromagnetic Compatibility (Emc); Technical Data - Würth WIG 180 DC Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Attention!
Improper checks for compliance with accident
prevention regulations may result in destruction of
the machine. Please contact an authorised Würth
service point for more information on checking the
compliance with accident prevention regulations.

Electromagnetic compatibility (EMC)

This appliance conforms to the current EMC
standards.
Please note:
Welding machines consume so much power that
they may affect public electricity networks. For this
reason the mains supply is subject to requirements
regarding the maximum permissible network
impedance. The maximum permissible mains im-
pedance (Z
) of the interface to the mains grid
max
(mains power supply) is specified in the technical
data. Contact the electricity network operator if
required.
The appliance is intended for welding both
in commercial and industrial environments
(CISPR 11 class A). Using the appliance in an-
other environment (e.g. in a residential area) may
affect electrical equipment in that area.
During start-up, electromagnetic problems may be
caused in:
• Power cables, control lines, signal and telecom-
munication lines in the vicinity of the welding /
cutting appliance
• TV and radio transmitters and receivers
• Computers and other control equipment
• Security equipment in commercial buildings (e.g.
alarm systems)
• Cardiac pacemakers and hearing aids
• Calibrating and measuring equipment
• Appliances with insufficient interference resist-
ance
If any other facility or equipment in
the surrounding area is affected, addi-
tional protective barriers may become
necessary.
The surrounding area to be taken into consider-
ation may extend beyond the boundaries of the
premises. This depends both on the type of the
building and on the other activities performed at
the site.
Always observe information and instructions
provided by the manufacturer when operating the
appliance. The company operating the appliance
is responsible for the setup and the operation of
the appliance.
If electromagnetic disturbances occur, the operating
company is responsible for the elimination of this dis-
tubances (with technical help from the manufacturer
if necessary).
Product features (Fig. I)
1 Detachable handle
2 Displays / operating elements
3 Negative connection socket
4 Positive connection socket
5 Main switch
6 Mains cable connection
7 Air inlet

Technical Data

Art.
Electrode welding range
TIG welding range
No-load voltage
Current setting
Duty cycle 100 %, 40%
Duty cycle 60 %, 40%
CDF at max. current, 40°C
Electrode diameter
Mains voltage
Frequency
Mains fuse
Max. current consumption Il
Max. rated power S1 (100%)
Power factor
Max. permissible mains imped-
ance Z
according to IEC 6100-
max
3-11/-12
Power cord
Mains plug
Protection class (IEC 529)
Cooling
Dimensions (L x W x H)
Weight
Protection class
5952 000 180
5 - 150 A
5 - 180 A
85 V
stepless
130 A
150 A
30 %
max. 4 mm dia.
230 V
50/60 Hz
16 A/tr
22.3 A
5.1 kVA
0.99 cos φ
23 mΩ
3 x 2.5 mm
2
Schuko 16 A
IP 23
F
337 x 130 x 211
mm
6.5 kg
/ I
21