Cembre B131-UC Manual De Uso Y Mantenimiento página 6

Herramienta hidraulica de compresión a batería
Tabla de contenido

Publicidad

ENGLISH
3.5) CRIMPING OF CONNECTORS ON COPPER CABLES
(Ref. to Figs. 2 and 3)
3.5.1) Connector crimping
– Fit adaptor AU130-C (see § 3.5.2).
– Select the appropriate die set for the connector.
– Insert die set into upper and lower die holders (see § 3.5.3).
– Insert the conductor in the connector.
– Position the connector between the dies and ensure the correct location of the crimp.
– To crimp connector continue as § 3.2.
3.5.2) Adaptor assembly
Insert the AU 130-C (09) adaptor in the guides on the U-fork (10) until securely located with
the grooves on the adaptor corresponding to the locators (06) on the U-fork head (10).
Remove the adaptor by pushing the adaptor off the locators and sliding from the head.
3.5.3) Dies assembly
– Press release botton (08) and insert the upper die (88) into the AU130-C adaptor (09)
until secured by the die retaining pin (07).
To remove the upper die, press the release button (86) and slide the die from the adaptor (09).
– Press release botton (04) and insert the lower die (89) into the seat on the ram (14)
until secured by the die retaining pin (02).
To remove the lower die, press the release button (04) and slide the die from the ram.
To facilitate this operation an advancement of 3-4 mm (0.12 - 0.16 in.) of the ram (14) is
suggested.
3.6) CRIMPING OF CONNECTORS ON ALUMINIUM CABLES
(Ref. to Figs. 4 and 5)
3.6.1) Pre-rounding conductor
(for sectoral cables)
– From the table (Fig. 6, page 42) select the adaptors and pre-rounding dies for the appro-
priate conductor size.
– Insert the upper adaptor AU130-... (98) and lower adaptor AC130-P (91) into the head
(see § 3.6.3).
– Insert the pre-rounding die into the AC130-P adaptor (see § 3.6.4).
– Position the conductor into the pre-rounding die (95) and locate the pre-rounding die in
the adaptor AU130-... (see § 3.6.4). Ensure that the pre-rounding die is correctly located
in the adaptor with its upper slot in line with the internal adaptor pins.
– Operate the tool until the dies are fully closed.
Release the hydraulic pressure (see § 3.4) and remove the compacted round conductor.
5