The sensing range can also be adjusted using just the potentiometer. We recommend
placing the sensing range in the object, e.g.
range has been adjusted, the object is removed from the path of the beam, which
causes the background to be suppressed and the switching output to change
table
4).
1
1...3 sec.
2
3
Figure 8: WTB26x-xxxxxx2xAxx, adjusting the sensing range with Teach-Turn adjustment
WTB26x-xxxxxx1xAxx with potentiometer:
The sensing range is adjusted with the potentiometer.
Clockwise rotation: Sensing range increased.
Counterclockwise rotation: Sensing range reduced.
We recommend placing the object within the sensing range, see figure 9 for an exam‐
ple. Once the sensing range has been adjusted, the object is removed from the path of
the beam, which causes the background to be suppressed and the switching output to
change
(see table
4).
COMMISSIONING