PROGRAMMING THE OPERATION LOGIC
Several operation modes of the unit are available to be chosen, by changing the dip-switch positions on the unit
accordingly. In the following, two tables are displayed explaining the functions associated to every single dip-switch for
both models.
FUNCTION
Pre-blinking
Automatic closing
Start while opening
Logica del comando di start
Rolling code
Photocell
CONNECTIONS TO THE TERMINAL UNIT
IMPORTANT:
Normally closed inputs (STOP, PHOTO), if not used,
must be bridged through the common terminal (-)
All manuals and user guides at all-guides.com
POSITION
1
2
3
4
5
6 - 7
8 - 9
10
11
12
13
14
15
16
15
DESCRIPTION
Active
Non-active
Active
Non-active
Not received
Received
Step-by-step function
START while opening command activates closing
Active
Non-active
Active also while opening
Non-active while opening
Motor power supply during the opening
Motor common terminal
Motor power supply during the closing
Power supply phase wire
Power supply neutral wire
Flasher 40 W
Power supply output 24 VAC / 6 W for photocells and
other attachments
Opening control for the connections of control devices
with normally open contact (led L2)
STOP command. Normally closed contact (led L3)
Common (-)
Photocell. Normally closed contact (led L4)
Antenna cable shielding
Antenna
Limit switch (FCA led L5 / FCC led L6)