Safety Devices; Maintenance; Cabinet Panels Disassembly; After The First 100 Operating Hours - FINI NUAIR NB4 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 52
ENGLISH
(Translation of the original instructions)
is facilitated.
Press the emergency stop button 3 in emergency cases ONLY.

3.5 Safety devices

● Operating pressure switch (see fig. 3/5): determines STOP and START pressures
● Oil level control (if provided).
1) Oil level is checked every 5 seconds during compressor standard operating mode. If the feeler detects a low oil
level for 12 times in a row, the compressor is stopped and the warning light (fig. 9 - ref. 2) turns on (steady
light).
What to do: power off and check the oil level, top up if necessary. Allow some minutes and then restart the
compressor. Should the machine stop once again, call an authorized service center.
2) If the light (fig. 9 - ref. 2) flashes after starting up the compressor or during compressor standard operation, the
following might have happened:
feeler short-circuited or contact open. Call an authorized service center in any case, as the feeler needs to be replaced.
Should the above happen, the compressor can work for 3 hours more. Then it should be powered off and on again
to continue working until the feeler is replaced.
● Oil level light (fig. 9).
ALWAYS CHECK OIL LEVEL BEFORE RESTARTING THE COMPRESSOR.
Close the air cock between compressor and tank (if present).

4.1 Cabinet panels disassembly

Front and upper panels have to be removed to access the compressor.
Front panel: use the key supplied with the machine to open the locks and remove panel by first pulling it upwards and
then outwards.
Upper panel: unscrew the 4 screws with a 5-mm socket wrench and lift the panel.
Never operate the compressor with the protection panels removed.

4.2 After the first 100 operating hours

● Check that all screws are tightened, with special attention to head screws.
Model
NB4
NB5 / NB7
NB10
● Check that all tubing connectors are tightened.
● Check that the terminals of all wires brought to the control panel are tightened.
● Check for any dust inside the cabinet to determine whether the conditions in the shop meet recommended requirements.
If so, the compressor should be cleaned.
● Change oil in the tank.
4.3 After the first 50 operating hours / 1st working week: oil level check and top-up
(fig. 10)
Check oil level, if the level is below MAX., remove rod A and top up through filler plug.

4.4 Every 300 hours / month: suction filter cleaning (fig. 11)

SPONGE FILTER : remove front plastic panel and remove the sponge element, wash in a solution containing normal
detergent, rinse and dry completely before refitting.
PAPER FILTER: Remove the metal half-shell and extract the paper item, clean by blowing compressed air.

4. MAINTENANCE

Before carrying out any maintenance operation:
Switch off the machine and the wall-mounted switch.
Bleed air from inside compressor and/or tank.
Torque
Head (Nm)
Flywhell (Nm)
27
45
45
28
28
75
24