Maintenance And Cleaning; Opening/ Closing The Container - Oase FiltoClear 3000 Instrucciones De Uso

Ocultar thumbs Ver también para FiltoClear 3000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

- English -

Maintenance and cleaning

Removing/inserting the UVC unit head
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Switch off the mains voltage prior to carrying out work on the unit.
Removing the UVC unit head
Figure (E)
How to proceed:
• Press the blue "Press" button (31) at the UVC unit head (4).
• Slightly turn the UVC unit head counter-clockwise.
• Carefully pull the UVC unit head out of the filter lid (8).
Inserting the UVC unit head
Figure (F)
Note!
The O ring (32) on the closure of the UVC water housing (4) is firmly clamped on. Only remove the O ring
when it must be replaced (e.g. when the O ring is porous).
How to proceed:
• Carefully insert the UVC unit head (4) into the filter lid.
• Turn the UVC unit head clockwise up to the stop.
The blue "Press" button engages (31).

Opening/ closing the container

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Switch off the mains voltage prior to carrying out work on the unit.
Opening the container
Figure (G)
How to proceed:
• Push back safety latch (36).
• Press the closing hook (35) inwards.
• Open and remove the clamping ring (10).
Closing the container
Figure (H, I)
How to proceed:
• Clean the channel (H 37) around the container rim.
• Grease the lid sealing ring (34) and place flush around the container (38) top edge.
• Press the filter lid (I 8) including the stack of foam filters on the container, if necessary, assist with your own body
weight.
• Place the clamping ring (10) around the container top edge (do not pinch the power cable) and assemble.
• Engage the closing hook (35).
• Push in the safety latch (36).
Cleaning the foam filters
The Easy-Clean function (actuate the cleaning handle and flush with water) allows easy cleaning of foam filters, UVC
unit and UVC water housing.
Figure (J, K, L)
How to proceed:
• Remove the closing cap from the drain hose or the dirty water drain socket (K 7). Attention: Do not lose the sealing
ring in the cap!
• Turn the function switch (5) counter-clockwise to "Cleaning foam filters" (41).
• Vigurously pull up the cleaning handle (3) several times, then push the handle down against the stop ("pumping"
action).
The foam filters will be rinsed by this action.
14

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Filtoclear 4000Filtoclear 8000

Tabla de contenido