10 Maintenance
DANGER:
e
Danger of electric shock.
Disconnect the unit and isolate the mains supply
before proceeding to carry out maintenance on
the unit. Ensure the the mains supply cannot be
reconnected inadvertently. This will prevent injuries.
DANGER:
e
Danger of electric shock.
Do not clean the unit with water.
WARNING:
b
Danger of breakdowns or malfunction.
Do not use gasoline, benzine, thinner or cleansers
when cleaning the unit. It may damage the coating
of the unit.
WARNING:
b
Hot water over 40ºC may cause discoloring or
deformation.
10.1
Cleaning the remote controller
• Wipe the controller with a dry cloth. Do not use water to
clean the remote controller.
• Do not use glass cleaners or chemical cloths.
10.2
Cleaning the indoor unit
• Wipe the outer part of the unit with a soft and dry cloth.
• For difficult stains, use a neutral detergent diluted in water.
Eliminate the excess of water form the cloth before wiping.
Leave the unit clean from any detergent.
10.3
Cleaning the air filters
The air filter traps the dust circulated from the room into the
indoor unit.
If the filter becomes blocked, the air conditioner's efficiency
will be reduced, the compressor could be damaged and the
indoor unit's heat exchanger coil could freeze up.
Clean the air filter regularly to prevent this from happening.
In order to do so:
• Remove the air filters by slightly pushing up the center tab
until it is released from the stopper and remove the filter
downwards.
VAI6-WN-U_EN - 10/13 - Vaillant
All manuals and user guides at all-guides.com
• Clean the filter removing the dust or the dirt using a
vacuum cleaner or cleaning them with cold water.
• Ensure that the filters are dried completely (dry in the
shade) before putting them back into the unit. The
activated carbon filters (where fitted) can be reactivated
by placing in direct sunlight. If strange odours are still
smelt replace with new. If strong odours continue to be a
problem, contact your after sales service provider to fully
clean the unit.
• Attach the filter correctly and make sure it is completely
fixed behind the stopper. If the right and left filters are not
properly fixed, this could cause a malfunction.
WARNING:
b
Danger of breakdowns or malfunction.
Do not attach perfume systems, anti-odour systems
etc. in the filter or in the inside air return.
This can damage and soil the heat exchanger coil. If
necessary, install these systems at the unit's outlet
point and ensure they only run when the fan is on.
10.4
Cleaning the Outdoor Unit
WARNING:
b
Always use suitable personal protection equipment
(helmet, gloves, safety boots and protective
glasses).
• Wipe the outer part of the unit with a dry cloth.
• Occasionally remove dust and leaves from the inlet
surface.
• Periodically clean the heat exchanger fins with a soft
brush when the unit is located in a dusty environment.
• Occasionally check the base of the outdoor unit.
DANGER OF INJURY AND PHYSICAL DAMAGE!
e
A damaged or deteriorated base could make the unit
unstable and potentially cause physical or material
damage.
DANGER OF INJURY AND PHYSICAL DAMAGE!
e
Except for servicing or replacement, do not
dismantle the outdoor unit outlet. Exposing the fan
can be very dangerous.
NOTE:
i
We advise you to contact a reliable air conditioner
specialist or the Vaillant Group Technical Service to
contract a preventative maintenance service. This
will help to prolong the life of your equipment and
improve its performance.
MAINTENANCE
EN