Introduction; Design Standard; Technical Features; Hydraulics Features - Aqua HC997-1 Manual De Programación

Ocultar thumbs Ver también para HC997-1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

HC997-999 – MOD. A
Digital multifunction solenoid metering pump
1.0

INTRODUCTION

The HC997-999 mod. A pump is a metering solenoid pump that can work in constant or proportional by an external
signal. In the bottom of the enclosure there are located an ON/OFF switch and an internal terminal block to connect
the different signals (level probe input, water meter input, flow sensor input, 4÷20mA input and relay output). Once
the pumps is switched on the display show an user menu and is possible to read some information regarding the
functioning mode and the possibility to pause and prime the pump. Thanks to the digital technology with the
microcontroller and an LCD display the HC997-999 pump is easy to program and to save all the statistics.
1.1
D
ESIGN STANDARD
Our pumps are built according to the actual general directives endowed with CE mark in conformity with the
following European directives:
n° 2004/108/CE " e s.m.i.
n° 2006/95/CE "DBT Low Voltage Directive" e s.m.i.
n° 2011/65/UE , 2012/19/UE "direttive RoHs e WEEE" e s.m.i.
1.2
T
ECHNICAL FEATURES
Power supply: 230VAC ± 10% – 50/60Hz
Consumption: see table below
Degree protection: IP65
1.3
H
YDRAULIC FEATURES
Max flow rate @
MODEL
Max pressure
L/h
2
HC997 - 1
5
7
7
HC997 - 2
8
10
3
HC997 - 3
4
5
10
HC997 - 4
12
14
2
HC997 - 5
2,5
3
Max flow rate @
MODEL
Max pressure
L/h
10
HC999 - 1
12
14
4
HC999 - 2
4,5
5
20
HC999 - 3
25
35
35
HC999 - 4
45
50
ADSP9000026
All manuals and user guides at all-guides.com
Weight: 2,5 kg Overall dimensions: W 118 x H 205 x D 147 mm
Strokes
Frequency (max)
bar
per min.
8
150
5
150
2
150
4
200
2
200
0
200
12
120
10
120
8
120
4
180
2
180
0
180
20
75
18
75
15
75
Strokes
Frequency (max)
bar
per min.
10
200
8
200
5
200
20
100
18
100
15
100
5
150
3
150
1
150
2
150
1
150
0,5
150
18/09/2015 Rev.1.5
Fuse: 1 A – Delayed
Volume
Consumption
per stroke
(max)
ml / stroke
watt
0,22
18
0,56
18
0,77
18
0,58
18
0,67
18
0,83
18
0,42
22
0,56
22
0,69
22
0,93
22
1,11
22
1,30
22
0,44
22
0,56
22
0,67
22
Volume
Consumption
per stroke
(max)
ml / stroke
watt
0,83
35
1
35
1,17
35
0,67
35
0,75
35
0,83
35
2,22
35
2,78
35
3,89
35
3,89
35
5
35
5,56
35
INTRODUCTION
ENGLISH
Size
Head pump
tubing
connections
mm
model
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
4x6
½" - PVDF
Size
Head pump
tubing
connections
mm
model
½" – PP
4x6
½" – PP
4x6
½" – PP
4x6
4x6
½" - PP
½" – PP
4x6
½" – PP
4x6
½" – PP
4x6/6x9
½" – PP
4x6/6x9
½" – PP
4x6/6x9
½" – PVC
10X14
½" – PVC
10X14
½" – PVC
10X14
22/100

Publicidad

Tabla de contenido
loading

Tabla de contenido