Tracing industrial control circuits.
1)
Ensure that the circuit is energized (closed at the panel) at a minimum. To maximize the
signal, close the other end of the circuit by turning on a load, such as a motor or pump.
2)
Clamp around the hot wire of this energized (closed) circuit.
3)
Use the magnetic strap to hang the battery pack onto the panel or the motor control cabinet.
4)
Plug the clamp into the battery pack.
5)
Set the receiver to the highest sensitivity (
If the receiver is saturated, reduce the sensitivity mode.
Battery Replacement
Note: Use only good quality alkaline batteries for maximum
operating life. Always replace with a complete set of new batteries
of the same type. Remove batteries as soon as they become
exhausted to avoid damage due to leakage. Remove the batteries
for storage lasting longer than 1 month or when the until will be
used infrequently.
Transmitter:
Ensure that the test leads are removed from the output
jacks and the circuit under test.
1)
Remove the battery cap by loosening the screw.
2)
Replace batteries with (4) new AA batteries.
3)
Re-fit cap and re-tighten the screw.
Receiver:
1)
Remove the battery cap by loosening the screw.
2)
Replace batteries with (3) new AA batteries.
3)
Re-fit cap and re-tighten the screw.
Battery Pack for Inductive Clamp:
Ensure the clamp is unplugged from the
battery pack.
1)
Remove cap by squeezing the ribbed tabs on
either side of the cap.
2)
Remove the battery holder noting the
orientation to the strap mount on the case.
3)
Replace batteries with (8) new C-cell batteries.
4)
Re-install battery holder into the case noting
the orientation to the magnetic strap mount.
5)
Snap cap back onto case.
) mode and trace the circuit to the other end.
Strap
Strap Mount
Mount
Page 19
Ribbed
Ribbed Tabs
Tabs