Jtrouble Shooting; Guarantee Conditions - Qlima P 126 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

J
TROUBLE SHOOTING
Problem
Cause
No power supply
The unit does
not function
Water tank indicator is on
In direct sunlight
Windows or doors open, many
people or heat source in room
The unit does
not seem to
Dirty filter
perform
Air inlet or air outlet blocked
Room temperature lower than
selected value
The unit is noisy Unit stands uneven
The compressor
Overheat protection probably
does not work
activated
Distance too great
Remote control
Remote control signal not
does not
detected by control panel
function
Batteries empty
Never attempt to disassemble or repair the device. Inexpert repairs invalidate the
guarantee and can endanger the users of the device.
K

GUARANTEE CONDITIONS

The air conditioner is supplied with a 24-month guarantee, commencing on the
date of purchase. All material and manufacturing defects will be repaired or
replaced free of charge within this period. The following rules apply:
1.
We expressly refuse all further damage claims, including claims for collateral
damage.
2.
Repairs to or replacement of components within the guarantee period will
not result in an extension of the guarantee.
3.
The guarantee is invalidated if any modifications have been made, non
genuine parts are fitted or repairs are carried out by third parties.
4.
Components subject to normal wear, such as the filter, are not covered by the
guarantee.
5.
The guarantee is valid only when you present the original, dated purchase
invoice and if no modifications have been made.
6.
The guarantee is invalid for damage caused by neglect or by actions that
deviate from those in this instruction booklet.
7.
Transportation costs and the risks involved during the transportation of the
air conditioner or air conditioner components shall always be for the account
of the purchaser.
8.
Damage caused by not using suitable Qlima filters is not covered by the gua-
rantee.
Solution
Connect to a functioning outlet
and switch on
Empty the internal water
container (refer to Chapter F)
Close curtains
Close doors and windows, or
place an extra air conditioner
Clean or replace filter
Remove blockage
Change temperature selection
Place on even surface (less
vibrations)
Wait 3 minutes until the
temperature has decreased, and
turn on the unit again
Make sure the remote control is
correctly aimed at the control
panel
Replace the batteries
4
99

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

P 129

Tabla de contenido