9 .2
OTHER FAULTS
Malfunction
Setting tool does not react
The LED for illumination of
the riveting point does not
come on or goes out again
immediately
Fastener not set correctly
Fastener not set correctly
Fastener is not unscrewed
correctly
Spin on mode does not
trigger spindle out
After switching on, the
setting tool does not
perform a calibration run
The protruding threaded
mandrel or bolt length
changes
52 | English
Possible cause
b.) No battery inserted
c.) Battery discharged
d.) The tool is locked
a.) Standby time for the LED foot
light set to "0" or a very short
time
b.) Foot LED defective
a.) Force set too high or too low
b.) Stroke set too high or too low
Spin on time too short
Spindle out time too short
a.) Setting tool switched off /
battery discharged
b.) Spin on mode set incorrectly
c.) Threaded mandrel or
threaded sleeve blocked
d.) Trigger defective
Software error
Software error
Remedy
a.) Insert battery.
b.) Charge the battery.
c.) Unlock tool, see chapter 3.3.
a.) Reset the standby time.
b.) Send the setting tool to HONSEL
Service, see chapter 5.4.
Set up the setting tool again, see
chapter 3.5.
Set up the setting tool again, see
chapter 3.5.
Adjust the spindle out time in menu
Expert / Spindle Settings / Set
spindle out time.
a.) Switch on the setting tool / replace
the battery.
b.) Check spin on mode in menu
Expert / Work Mode.
c.) Press the trigger once without a
fastener.
d.) Send the setting tool to HONSEL
Service, see chapter 5.4.
a.) Remove the battery and insert
again after 2 seconds.
b.) Send the setting tool to HONSEL
Service, see chapter 5.4.
a.) Remove the battery and insert
again after 2 seconds.
b.) Send the setting tool to HONSEL
Service, see chapter 5.4.