PROBLEM
The battery cannot be
fully charged via the mower
charging port.
The mower cannot be
started after cleaning.
It is easy for the mower to be
clogged.
The mower easily loses trac-
tion when climbing up on the
slope.
When the mower is stopped
on a slope with the parking-
brake pedal pressed, the
mower can roll down the
slope.
There is no water coming
from the wash port when at-
tempting to wash the deck.
An abnormal sound is heard
when manually pushing the
mower without starting it.
64
56-VOLT LITHIUM-ION ELECTRIC ZERO TURN MOWER — ZT5200L/ZT5200L-FC
CAUSE
Firmware bug of the riding mower or the battery
or the charger failure.
Improper cleaning, such as water getting on the
electric components, LCD screen etc.
The mower deck is clogged with grass and debris.
The tires of the rear wheels are worn.
Mowing on a steep slope.
The brake components are excessively worn due
to improper operation of the mower.
The wash-port quick coupler is not properly
mounted onto the wash port.
The sound comes from the magnets inside the
driving motor.
SOLUTION
Reset the charger by unplugging the charger and
waiting for longer than 1min. Then reconnect the
plug to the power supply. If this does not solve the
problem, call EGO Customer Service Center.
Follow the instructions in section "GENERAL
MAINTENANCE" and "CLEANING THE MACHINE" to
clean the mower correctly.
If the mower caught in rain accidentally, leave it for
over 12 hours to dry or use compressed air to dry it.
Clean the mower deck after each use, following the
section "Using Wash Port to Clean Mower Deck".
Seek local service to replace the wheel tires or when
the wheel itself is damaged replace the rear wheel
following the instructions in section "REPLACING THE
WHEELS".
The mower should not be used to mow slopes steeper
than 15 degrees.
Contact a qualified service technician for repair.
Re-attach the wash-port quick coupler until you hear
a clear click after firmly pushing. If it does not work,
call EGO Customer Service Center.
It is normal and no action is needed.