Product description

Control elements
6
1 LED display
2 Door OPEN button
3 STOP button
Programming control elements
1
3
4
1 LED display
2 LED spot (confirmation of
the programming entry)

Rating plate

The rating plate is located at the side on the control housing. Ob-
serve the power supply specifications.
1
7
Made in Germany
6
5
4
1 Control type
2 Manufacturer and address
3 Supply voltage
4 Amperage
4 Door CLOSE button
5 Housing cover
6 1/2 open button
2
5
3 Up navigation button
4 Down navigation button
5 Programming button (Prog
button)
2
3
5 Max. motor power
6 Protection type
7 Rating plate no.

Technical data

Control unit
Rating plate no.
Height x width x depth
Cable feed-throughs
1
Supply voltage
2
Control voltage
3
External power supply
4
Max. motor power
Safety according to
EN 13849-1:
5
Protection type
Operating temperature
Manufacturer
4

Installation

Hazardous voltage
DANGER
The product runs on high voltage Before starting
with the installation,observe the following:
Follow the instructions as well as the illustrations in the
"Connection diagrams" chapter.
1.
Tools required
For the assembly of the control, you require the following tools:
wooden folding rule or tape measure
cross-tip screwdriver Phillips; size 2
drilling machine
drill 6 mm
Torx screwdriver, size T20
slotted screwdriver for electricians
spirit level
marking pencil
2.
Opening the control cover
Open the housing cover by either loosening the two screws on
the left or right on the cover.
T100 R
T100 R
15331560850
250 mm x 215 mm x 120 mm
Assembled vertically
6 x M20
2 x M16
2 x M20 V cutout
3N~ 400 V
3~ 230 V
24 V DC
max. 700 mA
Max. 3.0 kW
Input STOP A: Cat 2 / PL = C
Input STOP B: Cat. 2 / PL = C
Input STOP C: Cat. 2 / PL = C
IP 54 / CEE plug = IP44
+50 °C
-20 °C
Novoferm tormatic GmbH
Eisenhüttenweg 6
D-44145 Dortmund
www.tormatic.de
Have all work on electrical connections car-
ried out by a skilled electrician.
The power connection must be executed in
compliance with the mains voltage avail-
able.