Descargar Imprimir esta página

Emergency Release - RIB SUPER 8000 FAST Instrucciones Simplificadas

Ocultar thumbs Ver también para SUPER 8000 FAST:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 3
SIMPLIFIED INSTRUCTIONS FOR SUPER 8000 FAST WITH L1-CRX
1° Connecting the motor and limit switch (done in the factory)
COMMON
STOP
PHOTOCELL 1
PHOTOCELL 2
EDGE 1
EDGE 2
COMMON
TIMER
PEDESTRIAN
SINGLE COMMAND
CLOSE
OPEN
COMMON
24Vdc 0,4A ±15%
A+TEST / A-
PHOTOCELLS
24Vdc 0,4A ±15%
AUTO-TEST
R=2,2K 1/4W
LED
COMMON
BLINKER
230Vac 40W MAX
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN openings
default NOT ACTIVATED and LED DL11 OFF (trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11 ON (trimmer
rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2 seconds to a maximum of 30 seconds.
2 – LIMIT SWITCH ADJUSTMENT
SUPER 8000 FAST has 4 independent watertight limit switches mounted on the motor-reducer,
that are set to command the start of the deceleration and the stop of the movement of the
gate in both directions.
Fix the decelaration cams CCA1643 and CCA1644 as shown in the drawing.
CCA1642
CCA1643
≥90cm
ITA
ESP ENG FRA GRE DEU RUS ARA THAI BUL FAR TUR
CCA1644
CCA1642
≥90cm
ANTENNA
433 MHz
ANTENNA
BRAIDING

EMERGENCY RELEASE

To be able to open the gate manually, open the cover with the appropriate key and turn handle
"A" in an anti-clockwise direction.
To restore the electric functioning operate in the opposite direction.
HIN
Install a
Residual Current Circuit
Breaker like
ABB F204A-25/0,3
CHI

Publicidad

loading