Issue
The outdoor unit
makes noises
Dust is emitted from
either the indoor or
outdoor unit
The unit emits a
bad odor
The fan of the outdoor
unit does not operate
Operation is erratic,
unpredictable, or
unit is unresponsive
NOTE: If problem persists, contact a local dealer or your nearest customer service center. Provide
them with a detailed description of the unit malfunction as well as your model number.
Troubleshooting
When troubles occur, please check the following points before contacting a repair company.
Problem
Poor Cooling
Performance
Possible Causes
The unit will make different sounds based on its current operating mode.
The unit may accumulate dust during extended periods of non-use, which will be
emitted when the unit is turned on. This can be mitigated by covering the unit during
long periods of inactivity.
The unit may absorb odors from the environment (such as furniture, cooking,
cigarettes, etc.) which will be emitted during operations.
The unit's filters have become moldy and should be cleaned.
During operation, the fan speed is controlled to optimize product operation.
Interference from cell phone towers and remote boosters may cause the unit to
malfunction.
In this case, try the following:
• Disconnect the power, then reconnect.
• Press ON/OFF button on remote control to restart operation.
Possible Causes
Temperature setting may be higher
than ambient room temperature
The heat exchanger on the indoor
or outdoor unit is dirty
The air filter is dirty
The air inlet or outlet of either
unit is blocked
Doors and windows are open
Excessive heat is generated
by sunlight
Too many sources of heat in the
room (people, computers,
electronics, etc.)
Low refrigerant due to leak
or long-term use
SILENCE function is activated
(optional function)
Solution
Lower the temperature setting
Clean the affected heat exchanger
Remove the filter and clean it according to
instructions
Turn the unit off, remove the obstruction
and turn it back on
Make sure that all doors and windows are
closed while operating the unit
Close windows and curtains during periods
of high heat or bright sunshine
Reduce amount of heat sources
Check for leaks, re-seal if necessary and
top off refrigerant
SILENCE function can lower product
performance by reducing operating
frequency. Turn off SILENCE function.