w CONNECTION OF A REMOTE OPERATION PANEL (ROP)
The ROP (AW-CB400) and the camera must be connected with the optional connecting cable AW-CA50T8.
1. Turn the OPERATE switch of ROP to OFF before connecting cables.
2. Connect the 50-pin connector of the connecting cable to I/F REMOTE connector of the camera.
The 10BASE-T cable must be connected to the ROP.
3. Turn the OPERATE switch of ROP to ON and the camera can be controlled remotely by the ROP.
DC cable with ø6.5 plug
(supplied with AW-PS505A)
Connecting cable AW-CA50T8 (10 m)
10BASE-T
cable
AC Adapter
AW-PS505A
- 29 (E) -
MONITOR
BNC
Remote Operation Panel AW-CB400
DC cable with 4-pin connector
(supplied with AW-PS505A)
AC Adapter
AW-PS505A