INSTALLATION CON'T.
5. Leak Testing
1. Turn all grill control knobs OFF.
2. Turn ON the home gas source.
3. Use a clean paint brush and a 50/50 mild soap and water solution. Brush soapy solution onto areas indicated. (see Figure 9).
4. If "growing" bubbles appear, there is a leak. Close main gas supply and re-tighten all connections. If leaks cannot be stopped do
not try to repair. Contact licensed plumber for correction.
5. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing
on that system at test pressures in excess of ½ psig (3.5kPa).
6. The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5kPa).
All manuals and user guides at all-guides.com
Figure 9
Side View
Natural Gas
Regulator
Gas Inlet Pipe
15