Toshiba RAV-RM561FT-EN Instrucciones De Montaje página 66

Ocultar thumbs Ver también para RAV-RM561FT-EN:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
DN setting
Code
(DN)
Data
0010
0000
Return
Fix
<
>
DN setting
Code
(DN)
Data
0010
0001
Return
Fix
<
>
DN setting
Continue?
Return
Yes
No
129-EN
3
Push the [
] / [
] button to select
"7. DN setting" on the "Field setting menu"
screen, then push the "
Set" [
Set
F2] button.
The fan and louver of the indoor unit operate.
When the group control is used, the fan and
louver of the selected indoor unit operate.
Move the cursor to select "Code(DN)" with the
"
< " [
F1] button, then set
<
"Code(DN)" with the [
] / [
]
button.
Move the cursor to select "Data" with the
> " [
"
F2] button, then set "Data"
>
with the [
] / [
] button.
4
Push the [
MENU] button to set the other
Code(DN) and Data. After "Continue?" is
displayed on the screen, push the
"
Yes" [
F1] button.
Yes
5
Push the "
No" [
F2] button to
No
finish the setting operation. " Setting"
appears on the screen for a while, then the
screen returns to the "Field setting menu"
screen.
Pushing the "
No" [
F2] button
No
displays the unit selection screen when the
group control is used. Push the [
CANCEL]
button on the unit selection screen to finish the
setting operation. " Setting" appears on the
screen for a while, then the screen returns to the
"Field setting menu" screen.
– 65 –
 Filter sign setting
According to the installation condition, the filter sign
term (Notification of filter cleaning) can be changed.
Follow to the basic procedure.
1
2
3
4
5
(
).
3
• For the "Code (DN)" in Procedure
, specify
3
• For the "Data" in Procedure
, select the Data of
filter sign term from the following table.
Data
Filter sign term
0000
None
150 H
0001
(Factory default)
0002
2500 H
0003
5000 H
0004
10000 H
 To secure better effect of
heating
When it is difficult to obtain satisfactory heating due to
installation place of the indoor unit or structure of the
room, the detection temperature of heating can be
raised. Also use a circulator or other machinery to
circulate heat air near the ceiling.
Follow to the basic procedure.
1
2
3
4
5
(
).
3
• For the "Code (DN)" in Procedure
, specify
3
• For the "Data" in Procedure
, select the Data of
shift value of detection temperature to be set up from
the following table.
Data
Detection temperature shift value
No shift
0000
(Factory default)
0001
+1 °C
0002
+2 °C
0003
+3 °C
0004
+4 °C
0005
+5 °C
0006
+6 °C
 8 °C operation
Pre-heating operation can be set for cold regions
where room temperature drops to below zero.
Follow to the basic procedure.
1
2
3
4
5
(
).
[0001].
• For the "Code (DN)" in Procedure
[00d1]
.
• For the "Data" in Procedure.
Data
8 °C Operation setting
None
0000
(Factory default)
0001
8 °C Operation setting
[0006].
3
, specify
130-EN

Publicidad

Tabla de contenido
loading

Tabla de contenido