Toshiba RAV-RM561FT-EN Instrucciones De Montaje página 69

Ocultar thumbs Ver también para RAV-RM561FT-EN:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26
[Procedure example]
Manual address setup procedure
While the operation stops, change the setup.
(Stop the operation of the unit.)
Field setting menu(2/2)
6. Setting timer operation mode
7. DN setting
8. Reset power consumption data
Return
Set
DN setting
1-1
2-2
1-2
3-1
2-1
3-3
Return
Unit
Set
Address is displayed here.
3-3
DN setting
Code
(DN)
Data
0012
0003
Return
Fix
<
>
3-3
DN setting
Code
(DN)
Data
0012
0002
Return
Fix
<
>
135-EN
1
Push the [
MENU] button to display the
menu screen.
2
Push and hold the [
MENU] button and
the [
] button at the same time to
display the "Field setting menu".
Push and hold the buttons for more than 4
seconds.
3
Push the [
button to select
] / [
]
"7.DN setting" on the "Field setting menu"
screen, then push the "
Set" [
Set
F2] button.
4
Push the "
unit" [
F1] button to
Unit
select the indoor unit "3 - 3" to be changed
manually.
The selected unit changes as follows each time
the button is pushed:
1-1
1-2
3-3
5
Push the "
Set" [
F2] button.
Set
The setting display for the selected unit
appears.
The fan and louver of the indoor unit operate.
When the group control is used, the fan and
louver of the selected indoor unit operate.
Line address change
Change "Code(DN)" from [0010] to [0012] with
the [
] / [
] button.
Change "Data" from [0003] to [0002] with the
[
] / [
] button.
Address is displayed here.
3-3
DN setting
Code
(DN)
Data
0013
0003
Return
Fix
<
>
3-3
DN setting
Code
(DN)
Data
0013
0002
Return
Fix
<
>
Address is displayed here.
3-3
DN setting
Code
(DN)
Data
0014
0001
Return
Fix
<
>
3-3
DN setting
Code
(DN)
Data
0014
0002
Return
Fix
<
>
– 68 –
6
Push the [
MENU] button to set the other
Code(DN) and Data. After "Continue?" is
displayed on the screen, push the
"
Yes" [
F1] button.
Yes
Indoor address change
Change "Code(DN)" from [0010] to [0013] with
the [
] / [
] button.
Change "Data" from [0003] to [0002] with the
[
] / [
] button.
7
Push the [
MENU] button to set the other
Code(DN) and Data. After "Continue?" is
displayed on the screen, push the
"
Yes" [
F1] button.
Yes
Group address change
Change "Code(DN)" from [0010] to [0014] with
the [
] / [
] button.
Change "Data" from [0001] to [0002] with the
[
] / [
] button.
8
Push the [
MENU] button to set the other
Code(DN) and Data. After "Continue?" is
displayed on the screen, push the
"
No" [
F2] button to finish the
No
setting operation. " Setting" appears on
the screen for a while, then the screen
returns to the "Field setting menu" screen.
Pushing the "
No" [
F2] button
No
displays the unit selection screen when the
group control is used. Push the [
CANCEL]
button on the unit selection screen to finish the
setting operation. " Setting" appears on the
screen for a while, then the screen returns to the
"Field setting menu" screen.
136-EN

Publicidad

Tabla de contenido
loading