Dismounting, Return And Disposal; Dismounting; Return - WIKA 831 Manual De Instrucciones

Manómetros con contacto inductivo para zonas potencialmente explosivas
Ocultar thumbs Ver también para 831:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

8. Dismounting, return and disposal

8. Dismounting, return and disposal
WARNING!
Physical injuries and damage to property and the environment through
residual media
Residual media in the dismounted instrument can result in a risk to persons, the
environment and equipment.
Wear the requisite protective equipment.
Observe the information in the material safety data sheet for the
corresponding medium.
Wash or clean the dismounted instrument, in order to protect persons and
the environment from exposure to residual media.

8.1 Dismounting

WARNING!
Risk of burns
During dismounting there is a risk of dangerously hot media escaping.
Let the instrument cool down sufficiently before dismounting it!
DANGER!
Danger to life caused by electric current
Upon contact with live parts, there is a direct danger to life.
The dismounting of the instrument may only be carried out by skilled
personnel.
Remove the instrument once the system has been isolated from power
sources.
WARNING!
Physical injury
When dismounting, there is a danger from aggressive media and high
pressures.
Observe the information in the material safety data sheet for the correspond-
ing medium.
Dismount the instrument when there is no pressure.
If necessary, the measuring line must have strain relief. For diaphragm pressure gauges, the
clamping bolts of the upper and lower flange must not be loosened.

8.2 Return

Strictly observe the following when shipping the instrument:
All instruments delivered to WIKA must be free from any kind of hazardous substances
(acids, bases, solutions, etc.) and must therefore be cleaned before being returned.
Pressure gauges with inductive contact model 831, for hazardous areas
EN
21

Publicidad

Tabla de contenido
loading

Tabla de contenido